If you live in St. Peters and have looked at the yearly water quality report from your supplier, you have probably seen a line about total trihalomethanes, usually shortened to TTHMs, and a line about haloacetic acids, usually shortened to HAA5. These two groups are on the report for a reason, and they are one of the few things a water softener will not change.
What these compounds are
Both groups are disinfection byproducts. They form when chlorine, which is added at the treatment plant to control germs in the water, reacts with natural organic matter already present in the source water. St. Peters draws on a mix of river water and groundwater, and source water carrying more natural organic matter can produce more of these byproducts once it is disinfected. TTHMs and HAA5 are names for families of related chemicals, not single substances, and the report usually tracks them as a group.
What a softener does and does not do
A water softener removes the minerals that make water hard, mainly calcium and magnesium. It does this by swapping those minerals for sodium on a resin bed. The unit is built for hardness minerals, not for dissolved organic byproducts, so softening will not lower TTHMs or HAA5 in the water coming out of your taps. A softener also adds sodium to the water it treats. Many St. Peters water reports describe high chloride and sodium in the source water, so it helps to keep the softener's effect on sodium in mind when you read the numbers and decide what to do.
Reading the report
- Find the table of disinfection byproducts and note the reported results beside each group, along with the regulatory limits printed next to them.
- Check whether the figures are described as system-wide averages or as results from specific sampling sites. A site near your neighborhood may differ from the average.
- Note the reporting year. Results change from season to season, and warmer months can bring higher readings, so a single year can be misleading.
- Look for any notes about changes in treatment at the plant. Changes in disinfection practice can shift byproduct levels over time.
Testing at your own tap
If you want to know what reaches your own faucet, a state-certified laboratory can test drinking water for these compounds. Ask the lab which methods it uses, what reporting limits apply, and whether it tests for the full TTHM and HAA5 groups. Follow the lab's sampling instructions exactly, including which tap to use and how to collect the sample. Home test strips and kits commonly aimed at hardness or chlorine do not measure these byproducts, so they are not a replacement for a lab result.
Options that target these compounds
Activated carbon is the usual material for reducing disinfection byproducts at the point of use. Carbon filters are typically installed under a kitchen sink or on a drinking water line, and they need replacement on the schedule the manufacturer lists. Whole-house carbon systems exist as well, but they are a larger decision with more installation and upkeep involved. Whatever you consider, read the performance data for the specific compounds you care about, since not every filter lists TTHMs or HAA5 as contaminants it reduces. Certification claims should be checked against the filter's own documentation, and installation and replacement details belong to the manufacturer's instructions.
Practical next steps
- Pull the most recent water quality report from your supplier and find the disinfection byproduct section.
- Decide whether a laboratory result from your own tap would answer your questions better than the system-wide average.
- If you have a softener, keep its service and salt records so you can match any changes in taste, scale, or water use against what the unit was doing at the time.
- If a filter is part of your plan, confirm which compounds it is documented to reduce before you buy, and set a replacement schedule the day it is installed.
- Talk with your health care provider if you have specific concerns about your household's water or about any member of your household.